Deionized Water Treatment Equipment Resin

Original
price: Negotiable
minimum:
Total supply:
Delivery term: The date of payment from buyers deliver within days
seat: Hebei
Validity to: Long-term effective
Last update: 2021-08-28 04:22
Browse the number: 340
inquiry
Company Profile
 
 
Product details

Deionized Water Treatment Equipment Resin

Deionized Water Treatment Equipment Resin 001x8

1、 Product introduction:

001×8 is a polystyrene matrix of gel type strong acid cation exchange resin containing sulfuric acid, which is equivalent to solid sulfuric acid. Mainly used for water treatment industry.

 

2、Index:

Name

Specification

Appearance

Pale yellow clear spherical beads

Polymer

  Styrene-DVB-Copolymer,gel-type  

Functional Group

-SO3H

Ionic Form

Na+

Weight Exchange Capacity

≥4.5mmol/g

  Volume Exchange Capacity  

≥2.0 mmol/ml

Real Density (g/ml)

1.26~1.30g/ml

Bulk Density (g/ml)

0.78~0.88g/ml

Water Retention Capacity

43%~48%

Particle Size Range

0.315~1.25 mm≥95

Uniformity Coefficient

≤1.6

Whole Bead Count(%)

≥95%

 

3、 Reference operating conditions:

Maximum operating temperature

120℃

Resin filling height

1~3m

Operating velocity

2~10BV/h

Backwash velocity

4~10BV/h

  Regeneration (desorption) velocity  

1~2BV/h

Regeneration agent

  2BV3~5%HCI,2BV2~4% NaOH  

 

4、 Applications:

1.Water softening

2.Preparation of pure water

3.Wet metallurgy

4.Rare element separation

 

5、Corresponding Brands:

1.Amberlite IRA-120

2.Dowex 50

3.KY2-8

4.Diaion SK-IA

 

6、 Precautions:

1.Resin should be wet state preservation. The best temperature is above 0℃. Resin should be put into a closed space or add in salt water of 5% or above if not used for a long time.Should be anti-freezing during transportation. Do not place heavy objects on the resin in case being crashed.

2.Generally requires alkali- water - acid - water flow path for processing. Strict requirement needs three circulation before coming to final ion kenel.

3.Need to consider different transformation expansion rate to set aside enough space to prevent resin overflow and ensure the appropriate liquid level height; Column diameter ratio should be within a reasonable range and avoid bias current; Use wet packed column or back-flushing to wash away bubbles inside resin layer.

4.Before liquid going into the resin column, steps as flocculation, filtration, or sand-filtration should be taken so that it doesn’t jam resin pore with suspended solids .

5.Resin inside the column that hasn’t been used for a long time should be storaged outside of the column after washing, or adding salt water in the salt resistant medium while keeping liquid level not dehydrated with usual backwashing to loosen resin in case of agglomeration.


http://www.cnumekresin.com/